Timber for loft conversions and home extensions: a buyer’s guide

Loft conversions typically need higher-grade structural carcassing timber (often C24) for floor joists, plus OSB3 sheet flooring; single-storey extensions usually need a mix of C16 or C24 framing timber and OSB3 or plywood boarding, depending on span and load.

Reviewed by Harry Major, Managing Director
Loft conversion under construction with exposed timber joists and rafters, OSB3 flooring partly laid and a spirit level and tape measure on a joist
Key takeaways
  • Loft conversions typically call for higher-grade structural timber (often C24) for joists, given the loads and spans involved – always confirm against your structural engineer's drawings and never assume.
  • Single-storey extensions usually need a mix of framing timber, flooring-grade sheet material and roofing timber, with grade depending on span and load.
  • C16 and C24 are the two structural grades you'll most likely be specifying – get familiar with the difference before you order, not after.
  • OSB3 is the standard choice for flooring and roof sheathing on both project types.
  • Getting quantities and delivery timing right from the start avoids the most common cause of delay – waiting on a top-up order mid-build.
  • On this page

     

    Whether it’s a full loft conversion or a single-storey rear extension, the timber and sheet material list can feel longer than expected once you get into the detail: joists, studwork, roofing timber, flooring boards, and the right grade for each.

    Get it right from the start and your build stays on programme. Get it wrong – order the wrong grade, or run short mid-fix – and you’re looking at delays, re-orders and a building site standing idle while you wait.

    This guide walks through what you’ll typically need for each project type, the grading decisions that matter, and how to get your quantities and delivery right first time.


    What timber do you need for a loft conversion?

    Loft conversions are structurally demanding compared with most domestic extensions, because you’re often introducing new floor joists that need to span the full width of the house while supporting a habitable room above the existing ceiling.

    This usually means:

    • Floor joists – typically cut from structural carcassing timber, specified at a higher structural grade (often C24) given the spans and loads involved, though the exact grade, size and spacing should always come from your structural engineer’s drawings rather than being assumed.
    • Roof timber – for dormer construction or roof alterations, additional structural softwood is needed for rafters, ridge boards and supporting timbers.
    • Studwork – for new stud walls, dormer cheeks and partition walls within the converted space.
      Sheet flooring – typically OSB3, laid across the new joists.

    Because loft conversions almost always involve building control sign-off, it’s worth having your structural engineer’s spec to hand before you order. This saves back-and-forth on grade and sizing once materials are already on site.

    What timber do you need for a single-storey extension?

    Extensions have a slightly different timber profile, depending on the build method:

    • Framing timber – for stud walls, whether the extension is built in timber frame or has timber internal partitions within a masonry shell.
    • Roof structure – rafters, wall plates and associated structural softwood, graded to the structural engineer’s specification.
    • Flooring and boarding – OSB3 for subfloors, or plywood where a smoother surface is specified.
    • First-fix carcassing – general structural softwood for noggins, battens and supporting timbers throughout the build.
    • Treated timber – for any timber in ground contact, within masonry cavities, or exposed to the elements during the build, treated timber protects against moisture and decay. Check whether your application needs it before ordering.

    As with loft conversions, span and load determine grade: a straightforward single-storey extension may only require standard C16 in many areas, but longer spans or heavier loads can call for C24. This is a decision for your structural engineer, not a default assumption either way.

    c16 vs c24 timber

    Choosing the right structural grade: C16 vs C24

    C16 and C24 are the two strength grades you’re most likely to be specifying across both project types.

    In short, C16 is a widely used structural grade suitable for many standard construction applications, while C24 offers higher strength and consistency, often chosen for longer spans or heavier loads.

    We’ve covered this in full detail, including how the grading works and when each is typically specified, in our C16 vs C24 timber guide. This is worth a read alongside your drawings before you place an order.

    Sheet materials for flooring and boarding

    OSB3 is the standard choice for flooring and roof sheathing on both loft conversions and extensions. It’s strong, cost-effective across a large area, and suited to the structural loads involved.

    Where a smoother finished surface is specified, plywood is sometimes used instead for flooring – see our guide to MDF vs OSB vs plywood if you’re weighing up which board fits your job.

    Our OSB3 is stocked in 11mm and 18mm thicknesses, in standard 8×4 sheets.

    Getting your quantities and delivery right

    Loft conversions and extensions are rarely single-delivery jobs. Timber often needs to arrive in phases as the build progresses, from first-fix structural timber through to later-stage boarding.

    Two things make this process easier:

    Get an accurate quote from clear information

    The more detail you can share upfront – products, quantities, delivery dates and site access – the more accurately your supplier can quote and plan.

    Our guide on how to get a fast timber quote and delivery covers exactly what to have ready.

    Plan deliveries around your build phases

    Phased ordering avoids storage issues on a live site and reduces the risk of delays.

    Our guide on how to plan timber deliveries to avoid delays on site has a practical checklist for this.

    Loft conversion and extension timber checklist

    Project stage Typical timber needed Grade/spec
    Loft floor joists Structural softwood carcassing Often C24 – confirm against structural engineer's drawings
    Loft/extension roof structure Rafters, ridge boards, wall plates C16 or C24, per structural engineer's spec
    Stud walls and partitions Structural softwood carcassing C16 or C24, per structural engineer’s spec
    Subfloors OSB3 (or plywood for a smoother finish) 11mm/18mm OSB3
    First-fix carcassing General structural softwood Per drawings

    Still not sure? Talk to our team

    Whether you’re planning a loft conversion, a rear extension, or both, our team can help you specify the right grades, sizes and quantities from your drawings – and plan deliveries around your build.

    This guide is provided for general reference only and does not replace project-specific structural design. Timber grades, sizes and quantities should always be confirmed against your structural engineer’s calculations and Building Control requirements before ordering. South London Timber can supply and advise against a confirmed specification, but strongly recommends professional structural sign-off for all loft conversion and extension work.

    Frequently asked questions

    Do I need C24 timber for a loft conversion?

    Loft conversions often call for C24 given typical joist spans and loads, but this isn't a fixed rule – the correct grade depends on your specific structural design. Always confirm against your structural engineer's drawings, and speak to our team if you need help sourcing the exact grade and sizes specified.

    Can I use C16 timber for a home extension?

    In many cases, yes – C16 is a widely used structural grade for standard domestic construction. Longer spans or heavier loads may call for C24 instead, so this should be confirmed against your project's structural drawings rather than assumed.

    How much timber should I order for an extension or loft conversion?

    This depends entirely on your project's design and phasing. Rather than estimating, share your drawings and specification with our team – we'll quote accurately against the actual requirement and help plan deliveries around your build stages.

    On this page

    Need help choosing the right timber?

    Tell us what you are building and we will recommend the right grade, size and quantity, with delivery across London and Kent.

    More timber advice

    26 Oct 2026
    ·
    5 min read
    Looking for timber cut to size in London or Kent? South London Timber supplies cut-to-size sheet materials and machines timber to order, with other sizes available on request across our range. This guide covers standard sizes, what you can order to size and what to tell us for an accurate quote.
    Read the guide →
    5 Oct 2026
    ·
    7 min read
    Not sure whether your job calls for MDF, OSB3 or plywood? Here's a straight, no-jargon comparison of the three – by use, by project type, and by how they cut and fix – so you can pick the right board first time.
    Read the guide →
    7 Sep 2026
    ·
    7 min read
    Formwork timber and formwork plywood shape and support concrete as it cures – but the wrong panel, grade or reuse count can cost you finish quality, time and money. Here's how to choose the right combination for your pour.
    Read the guide →